WB2K

Xem kết quả: / 0
Bình thườngTuyệt vời 

Technical Data.

 

Number of Coats: 2

Spreading Rate Per Coat: 5-8 m2 / L

Wet Film Per Coat: 125-200 microns

Recoat (@25oC): 4-6 hours

Curing time: 2-3 days

Colour: Light Grey

Thinner: 5% Water (if required)

Shelf Life: 6 months

Properties Test Procedure Results

Salt Resistance

Hot Water Resistance

Abrasion Resistance

Solvent Resistance

Acid Resistance

Alkali Resistance

VOC Content

 

 

 

 

 

 

SCAQMD 304-91

Excellent

Excellent

Excellent

Poor

Good(low concentrates)

Good

190 g/ L

Test have shown that CROMFLOORTM WB2K, when applied over concrete, will withstand a hydrotatic pressure of approximately 210kPa for up to 36 hours.(Negative head of pressure = 20.7m )

Application Guide.

 

Surface Preparation

  1. Concrete surface should be free from grease and oil - if necessary,clean with industrial grade degreaser of apply a poultice.
  2. Steps must be taken to remove laitance. This is best carried out by using either mechanical abrasion or acid etching. Upon completion of etching, neutralise, rinse thoroughly and allow to dry.
  3. Loose or weak concrete should be removed and the surface repaired by first priming with CROMFLOORTM WB2K, Fill up all voids using a mix of one part of the CROMFLOORTM WB2K mixed to 4 parts of clean fine sand.

Application Procedure and Equipment

  1. Mix Parts 1 and 2 separately first.
  2. Do not mix more product than will be used in 40 minutes as curing will occur. Note Recommended at 25oC and 50% relative humidity. An increase in temperature will reduce the amount of product to be mixed. A decrease in temperature will increase the amount of product that can be mixed.
  3. Mix equal parts of Part 1 and Part 2 together thoroughly. It is strongly suggested to use a high speed drill and propeller mixing blade. Mix for at least 3 - 4 minutes.
  4. Aplly by roller, brush or airless spray.
  5. In cold weather 5% water can be added after Part 1 and Part 2 have been mixed together.
  6. To provide a light profile slip resistant finish add Crommelin Slip Resistant Additive(SRA) to mixed CROMFLOORTM WB2K at the rate to achieve the desired finish(i.e. 100 g/L).
  7. To apply a slip resistant profile adjustable to requirements broadcast dry graded aggregrate into the wet 1st coat and allow to dry. Remove excess aggregate and over coat with 2nd coat.

Precautions.

 

  1. Do not apply to surfaces that are below 10oC or when relative humidity is above 85%.
  2. Poor mixing or inaccurate mixing ratios will result in variable cure and less than optimum hardness.
  3. Never add more than 10% water.
  4. Do not apply latex adhesives or sealants before CROMFLOORTM WB2K is hard dry.

Transport and Storage.

 

Sizes: 8L kit , 20L kit

Weights: 10 kg, 25 kg

Dangerous Goods Class: N/A

Flash Point: N/A

UN Number: N/A

Thống kê

Các thành viên : 195
Content : 276
Liên kết web : 7
Số lần xem bài viết : 1883875
mod_vvisit_countermod_vvisit_countermod_vvisit_countermod_vvisit_countermod_vvisit_countermod_vvisit_countermod_vvisit_countermod_vvisit_counter
mod_vvisit_counterToday29
mod_vvisit_counterYesterday187
mod_vvisit_counterThis week1628
mod_vvisit_counterThis month6078
mod_vvisit_counterAll1256488

Khách Online

Hiện có 23 khách Trực tuyến